VOC DESTRUCTION

KRONUS RTOs are designed to destroy 98% of the VOCs present in the process inlet stream to the RTO.  In standard configuration, KRONUS RTOs are guaranteed for 95%¹ VOC destruction.  KRONUS RTOs can be tuned by Alliance Corporation to enhance the VOC destruction up to a guaranteed to 98%¹.  The enhanced VOC destruction is achieved by extending the duration between flow direction changes to reduce the ratio of the entrained volume to the process flow.  This extended duration will decrease the thermal efficiency; however, on many processes where this technique is applicable there are sufficient VOCs available to offset the thermal efficiency losses.  There are instances where KRONUS RTOs have achieved 99% VOC destruction in the field.

1. If all of the Performance Conditions defined in the Proposal are satisfied, then the RTO will reduce the concentration of hydrocarbons measured at the exhaust as compared to the concentration of the inlet to the RTO by an average of greater than the stated percentage or down to 25 Parts Per Million Volume (PPMV) measured as C1 in the exhaust from the RTO.  Please refer the standard terms and conditions included with the Proposal for further detail.